Exams › GATE › Technical
Distributed winding and short chording employed in AC machines will result in
- increase in emf and reduction in harmonics.
- reduction in emf and increase in harmonics.
- increase in both emf and harmonics.
- reduction in both emf and harmonics.
Correct answer: reduction in both emf and harmonics.
Solution
Distributed winding and short chording help to smooth out the magnetic field in AC machines, which leads to a reduction in the generated electromotive force (emf) and minimizes the presence of harmonics, resulting in a more efficient operation.
Related GATE Technical questions
- The equivalent circuits of a diode, during forward biased and reverse biased conditions, are shown in the figure. If such a diode is used in clipper circuit of figure given above, the output voltage (vₒ) of the circuit will be
- An input device is interfaced with Intel 8085A microprocessor as memory mapped I/O. The address of the device is 2500H. In order to input data from the device to accumulator, the sequence of instructions will be
- In a stepper motor, the detent torque means
- A two machine power system is shown below. Transmission line XY has positive sequence impedance of Z1 Ω and zero sequence impedance of Z0 Ω.
An ‘a’ phase to ground fault with zero fault impedance occurs at the centre of the transmission line. Bus voltage at X and line current from X to F for the phase ‘a’, are given by Va Volts and Ia Amperes, respectively. Then, the impedance measured by the ground distance relay located at the terminal X of line XY will be given by
- The impulse response of a causal linear time-invariant system is given as h(t). Now consider the following two statements:
Statement (I): Principle of superposition holds
Statement (II): h(t) = 0 for t < 0
Which one of the following statements is correct?
- It is desired to measure parameters of 230 V / 115 V, 2 kVA, single-phase transformer. The following wattmeters are available in a laboratory:
W1: 250 V, 10 A, Low Power Factor
W2: 250 V, 5 A, Low Power Factor
W3: 150 V, 10 A, High Power Factor
W4: 150 V, 5 A, High Power Factor
The wattmeters used in open circuit test and short circuit test of the transformer will respectively be
⚔️ Practice GATE Technical free + battle 1v1 →