A single-phase triac based A C voltage controller feeds a series R L load. The input A C supply is 230 V, 50 Hz. The values of R and L are 10 Ω and 18.37 mH, respectively. The minimum triggering angle of the triac to obtain controllable output voltage is
- 15°
- 30°
- 45°
- 60°
Correct answer: 30°
Solution
The minimum triggering angle of 30° is required to ensure that the triac can effectively control the output voltage across the RL load, allowing for sufficient time for the inductor to build up its magnetic field and avoid excessive current spikes.
Related GATE Technical questions
- If the input x(t) and output y(t) of a system are related as y(t) = max(0, x(t)), then the system is
- Two discrete-time linear time-invariant systems have impulse responses h1[n] = δ[n−1] + δ[n+1] and h2[n] = δ[n−1] + δ[n+1], where δ[n] is the Kronecker delta. The overall system is
- Consider a power system consisting of N number of buses. Buses in this power system are categorized into slack bus, PV buses and PQ buses for load flow study. The number of PQ buses is N_L. The balanced Newton-Raphson method is used to carry out load flow study in polar form. H, S, M, and R are sub-matrices of the Jacobian matrix J as shown below:
[ΔP]
[ΔQ] = J [Δδ]
[ΔV], where J = [H S
M R]
The dimension of the sub-matrix M is
- Inductance is measured by
- In the Nyquist plot of the open-loop transfer function G(s)H(s) = (3s + 5)/(s - 1) corresponding to the feedback loop shown in the figure, the infinite semi-circular arc of the Nyquist contour in s-plane is mapped into a point at
- Consider a unity-gain negative feedback system consisting of the plant G(s) (given below) and a proportional-integral controller. Let the proportional gain and integral gain be 3 and 1, respectively. For a unit step reference input, the final values of the controller output and the plant output, respectively, are
G(s) = 1/(s - 1)
⚔️ Practice GATE Technical free + battle 1v1 →