A 3-phase, star-connected, balanced load is supplied from a 3-phase, 400 V (rms), balanced voltage source with phase sequence R-Y-B, as shown in the figure. If the wattmeter reading is -400 W and the line current is I_R = 2 A (rms), then the power factor of the load per phase is

  1. Unity
  2. 0.5 leading
  3. 0.866 leading
  4. 0.707 lagging

Correct answer: 0.5 leading

Solution

The power factor is calculated using the formula for real power in a balanced three-phase system, which relates the total power, line current, and phase voltage. Given the negative wattmeter reading indicates a leading power factor, and the calculated value aligns with 0.5, it confirms that the load is indeed operating at a 0.5 leading power factor.