Exams › GATE › Technical
The type of single-phase induction motor, expected to have the maximum power factor during steady state running condition, is
- split phase (resistance start).
- shaded pole.
- capacitor start.
- capacitor start, capacitor run.
Correct answer: capacitor start, capacitor run.
Solution
The capacitor start, capacitor run motor is designed to improve both starting torque and efficiency, resulting in a higher power factor during steady state operation compared to other types of single-phase induction motors.
Related GATE Technical questions
- For an ideal MOSFET biased in saturation, the magnitude of the small signal current gain for a common drain amplifier is
- The most commonly used relay, for the protection of an alternator against loss of excitation, is
- The geometric mean radius of a conductor, having four equal strands with each strand of radius ‘r’, as shown in the figure below, is
- The Bode magnitude plot of a first order stable system is constant with frequency. The asymptotic value of the high frequency phase, for the system, is −180°. This system has
- In the circuit shown below, a three-phase star-connected unbalanced load is connected to a balanced three-phase supply of 100√3 V with phase sequence ABC. The star connected load has Z_A = 10 Ω and Z_B = 20∠60° Ω. The value of Z_C in Ω, for which the voltage difference across the nodes n and n' is zero, is