Two wattmeter method is used for measurement of power in a balanced three-phase load supplied from a balanced three-phase system. If one of the wattmeters reads half of the other (both positive), then the power factor of the load is
- 0.532
- 0.632
- 0.707
- 0.866
Correct answer: 0.866
Solution
In a balanced three-phase system, when one wattmeter reads half of the other, it indicates a specific relationship between the active power and the reactive power, leading to a power factor of 0.866, which corresponds to a cosine of 30 degrees.
Related GATE Technical questions
- In a salient pole synchronous motor, the developed reluctance torque attains the maximum value when the load angle in electrical degrees is
- A single phase fully controlled rectifier is supplying a load with an anti-parallel diode as shown in the figure. All switches and diodes are ideal. With which one of the following is true for instantaneous load voltage and current?
- A positive charge of 1 nC is placed at (0, 0, 0.2) where all dimensions are in metres. Consider the x-y plane to be a conducting ground plane. Take ε0 = 8.85×10⁻¹² F/m. The z component of the E field at (0, 0, 0.1) is closest to
- A continuous-time input signal x(t) is an eigenfunction of an LTI system, if the output is
- Consider a system governed by the following equations
dx1(t)/dt = x2(t) - x1(t)
dx2(t)/dt = x1(t) - x2(t)
The initial conditions are such that x1(0) < x2(0) < ∞. Let x1f = lim(t→∞) x1(t) and x2f = lim(t→∞) x2(t). Which one of the following is true?
- The three-dimensional state of stress at a point is given by σ = [[10, 0, 0],[0, 40, 0],[0, 0, 0]] MPa. The maximum shear stress at the point is
⚔️ Practice GATE Technical free + battle 1v1 →